Symptoms
A crackle effect appears, random
cracks all over the surface
Cause
-
Coating system too brittle
for the substrate
-
Layers applied too thickly
-
Coatings applied at too low
temperature and/or too high
relative humidity
-
Applied product cannot follow
the movements of the substrate
-
Contamination between layers
Solution
Coating layers that are not sound should be removed. After the right pre-treatment, a new system should be applied.